{"product_id":"synovex-plus","title":"Synovex Plus","description":"\u003cdiv class=\"product-short-description mb-4\"\u003eSynovex Plus cattle implants are specifically developed to deliver superior performance in feed efficiency and cost of gain. Provides the right combination of two proven growth promoting compounds – estradiol benzoate (28 mg) and trenbolone acetate (200 mg). Foil-lined pouch packaging requires no refrigeration.\u003c\/div\u003e\n\u003cdiv class=\"product-short-description mb-4\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-short-description mb-4\"\u003eRecommended for increased rate of weight gain and for improved feed efficiency in steers; for increased rate of weight gain in heifers fed in confinement for slaughter.\u003c\/div\u003e\n\u003cdiv class=\"product-short-description mb-4\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-short-description mb-4\"\u003e\u003cstrong\u003eThis item cannot be shipped to California.\u003c\/strong\u003e\u003c\/div\u003e\n\u003ch3 class=\"product-short-description mb-4\"\u003eSynovex Plus Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBox of 10 x 10 cartridge implants (100 dose)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"product-short-description mb-4\"\u003e\n\u003ch3 class=\"Body\"\u003e\n\u003cspan class=\"Bold\"\u003eDirections for Use:\u003c\/span\u003e \u003c\/h3\u003e\n\u003cp class=\"Body\"\u003eAdminister one SYNOVEX Plus\u003cspan\u003e \u003c\/span\u003eimplant (eight pellets), containing 200 mg trenbolone acetate and 28 mg estradiol benzoate, to each steer or heifer by subcutaneous implantation in the middle-third of the ear. If using in a reimplantation program, reimplant steers or heifers with a SYNOVEX Plus\u003cspan\u003e \u003c\/span\u003eimplant 60 to 120 days after administering a SYNOVEX Choice\u003cspan\u003e \u003c\/span\u003eimplant.\u003c\/p\u003e\n\u003cp class=\"Body\"\u003eUse only a SYNOVEX applicator. Approved implantation technique is fully described in the foldout carton section.\u003cspan\u003e \u003c\/span\u003e\u003cb class=\"Bold\"\u003eNever sacrifice careful, clean technique for speed of implantation.\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/rjmatthews.cvpservice.com\/public\/product\/ssdLabel\/docFile?uuid=b9153fef-1a40-41bc-8b27-528930f1d9ec\" border=\"0\"\u003e\n\u003cp class=\"Label\"\u003e\u003cb class=\"Bold\"\u003eHow to Implant:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"Label\"\u003e\u003cb class=\"Bold\"\u003eFor Use With Any SYNOVEX Applicator\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"BodyKwn\"\u003eStudy the following instructions carefully, then proceed step by step, until the technique becomes routine. Many head can be implanted per hour by an experienced team, one member of which should be assigned to do nothing but the implantation. Care should be taken to insure the hands of the person administering the implant are clean and only sanitary instruments are used.\u003c\/p\u003e\n\u003cp class=\"Label\"\u003e\u003cb class=\"Bold\"\u003eSTEP 1 Loading The Applicator\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/rjmatthews.cvpservice.com\/public\/product\/ssdLabel\/docFile?uuid=3ba46885-8090-4841-a437-dabe01c98ddd\" border=\"0\"\u003e\n\u003cp class=\"Body\"\u003eLoad the applicator following the directions outlined in the instruction manual accompanying each applicator.\u003c\/p\u003e\n\u003cp class=\"Body\"\u003e\u003cb class=\"Bold\"\u003eAdditional information for the individual applicator user guides can be found at:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cb class=\"Bold-Underline\"\u003ewww.growwithsynovex.com\u003c\/b\u003e\u003cb class=\"Bold\"\u003e.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"Label\"\u003e\u003cb class=\"Bold\"\u003eSTEP 2 Restraint\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/rjmatthews.cvpservice.com\/public\/product\/ssdLabel\/docFile?uuid=e56b5a49-beaa-483b-9640-721be182415c\" border=\"0\"\u003e\n\u003cp class=\"Body\"\u003eThe animal must be confined in a restraint mechanism (squeeze chute or head gate). The implant site on the back of the ear should be prepared by scrubbing with a firm bristled brush that has been soaked in a germicidal solution.\u003c\/p\u003e\n\u003cp class=\"Body\"\u003e\u003cb class=\"Bold\"\u003eNote:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eIf implanting horned cattle, greater safety is provided when the head is controlled by the use of a bull lead (nose tongs).\u003c\/p\u003e\n\u003cp class=\"Label\"\u003e\u003cb class=\"Bold\"\u003eSTEP 3 Implant Site\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/rjmatthews.cvpservice.com\/public\/product\/ssdLabel\/docFile?uuid=e27cf4a2-6e1d-4893-b3c3-7c7ab6751a7f\" border=\"0\"\u003e\n\u003cp class=\"Body\"\u003eDivide the ear into three imaginary sections as illustrated. The implanted pellets should be deposited in the center one-third of the ear as shown. To accomplish this, the applicator needle should be inserted in the\u003cspan\u003e \u003c\/span\u003e\u003cb class=\"Bold\"\u003eouter\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eone-third of the ear as indicated by the “X” in the illustration. Implanting too close to the head may cause abnormal sexual behavior. Care should be taken to avoid severing the major arteries of the ear.\u003c\/p\u003e\n\u003cp class=\"Label\"\u003e\u003cb class=\"Bold\"\u003eSTEP 4 Insert Needle\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/rjmatthews.cvpservice.com\/public\/product\/ssdLabel\/docFile?uuid=2730b749-de3d-4b06-9c87-97066d46ae4d\" border=\"0\"\u003e\n\u003cp class=\"Body\"\u003eGrasp the ear with one hand. Holding the applicator firmly with the other hand, penetrate the skin at the point shown by the “X”. Thrust the needle under the skin taking care not to penetrate the cartilage. Ease the applicator forward (toward the base of the ear) until the full needle length is beneath the skin.\u003c\/p\u003e\n\u003cp class=\"Label\"\u003e\u003cb class=\"Bold\"\u003eSTEP 5 Pellet Implantation\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/rjmatthews.cvpservice.com\/public\/product\/ssdLabel\/docFile?uuid=f43f7246-cca1-4a7f-9f46-6b747a8fb83a\" border=\"0\"\u003e\n\u003cp class=\"Body\"\u003eWhen the needle is completely inserted, activate the instrument by squeezing the trigger completely. Refer to instructions for individual applicator.\u003c\/p\u003e\n\u003cp class=\"Label\"\u003e\u003cb class=\"Bold\"\u003eSTEP 6 Inspection\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/rjmatthews.cvpservice.com\/public\/product\/ssdLabel\/docFile?uuid=d667c75d-15b1-4c08-b452-f14d0a1661f4\" border=\"0\"\u003e\n\u003cp class=\"Body\"\u003eCheck the implant site. If properly administered, the implants should lie in a straight line under the skin.\u003c\/p\u003e\n\u003cp class=\"Body\"\u003eRe-cock the applicator. Disinfect the applicator needle in a germicidal solution. The applicator is now ready to implant the next animal.\u003c\/p\u003e\n\u003ch3\u003eWithdrawal Periods and Residue Warnings:\u003c\/h3\u003e\n\u003cp\u003eNo withdrawal period is required when used according to labeling.\u003c\/p\u003e\n\u003cp\u003eDo not use in beef calves less than 2 months of age, dairy calves, and veal calves. A withdrawal period has not been established for this product in pre-ruminating calves.\u003c\/p\u003e\n\u003cp\u003eDo not use in dairy cows or in animals intended for subsequent breeding. Use in these cattle may cause drug residues in milk and\/or in calves born to these cows.\u003c\/p\u003e\n\u003cp\u003eImplant pellets subcutaneously in ear only. Any other location is a violation of Federal law. Do not attempt salvage of implanted site for human or animal food.\u003c\/p\u003e\n\u003ch3\u003eUser Safety Warnings: \u003c\/h3\u003e\n\u003cp\u003eNot for use in humans. Keep out of reach of children.\u003c\/p\u003e\n\u003ch3\u003eAnimal Safety Warnings: \u003c\/h3\u003e\n\u003cp\u003eBulling has occasionally been reported in implanted steers and heifers. Vaginal and rectal prolapse, udder development, ventral edema and elevated tailheads have occasionally been reported in heifers administered SYNOVEX Plus implants.\u003c\/p\u003e\n\u003ch3 class=\"Body\"\u003eStorage:\u003c\/h3\u003e\n\u003cp class=\"Body\"\u003eStore unopened product at controlled room temperature 20°-25°C (68°-77°F) with excursions between 15°-30°C (59°-86°F). Avoid excessive heat and humidity. Use product before the expiration date on the label.\u003c\/p\u003e\n\u003cp class=\"Body\"\u003eOnce the pouch is opened, unused product may be stored in the end-folded pouch (away from light) for up to six months under refrigerated conditions 2°-8°C (36°-47°F) or at room temperature 20°-25°C (68°-77°F) with excursions between 15°-30°C (59°-86°F) for up to one month.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Zoetis","offers":[{"title":"Default Title","offer_id":46609753768094,"sku":null,"price":478.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0401\/2186\/0254\/files\/11740-1.jpg?v=1773626391","url":"https:\/\/houlihansaddlery.com\/products\/synovex-plus","provider":"Houlihan Saddlery LLC","version":"1.0","type":"link"}