{"product_id":"synovex-one-grower","title":"Synovex One Grower","description":"\u003cp\u003e\u003cspan\u003eSynovex One Grower cattle implants are a growth-promoting implant containing 150 mg of \u003c\/span\u003e\u003cspan\u003etrenbolone acetate and 21 mg of estradiol benzoate with a pore-forming \u003c\/span\u003e\u003cspan\u003epolymer coating. When administered properly, the implant will improve \u003c\/span\u003e\u003cspan\u003eweight gain for up to 200 days.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eThis item cannot be shipped to California. \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSynovex One Grower Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul id=\"product-features-list\" class=\"mb-0\"\u003e\n\u003cli\u003ePatented pore-forming barrier gradually and consistently releases active ingredients, helping extend implant duration\u003c\/li\u003e\n\u003cli\u003eTailored to needs; delivers proven return on investment\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-lg-3\"\u003e\n\u003cdiv class=\"product-short-description mb-4\"\u003eNow approved for use in pasture cattle\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eEach box contains 100 doses\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"Body\"\u003e\n\u003cspan class=\"Bold\"\u003eDirections for Use:\u003c\/span\u003e \u003c\/h3\u003e\n\u003cp class=\"Body\"\u003eEach cartridge cell holds one implant (6 pellets), containing 150 mg trenbolone acetate and 21 mg of estradiol benzoate. Administer complete contents of one cartridge cell (one implant) to each steer or heifer by subcutaneous implantation in the middle one-third of the ear.\u003c\/p\u003e\n\u003cp class=\"Body\"\u003eThe ten-dose cartridge of Synovex One Grower is designed to be used exclusively with a Synovex applicator. Approved implantation technique is fully described in the fold-out carton section.\u003cspan\u003e \u003c\/span\u003e\u003cb class=\"Bold\"\u003eNever sacrifice careful, clean technique for speed of implantation.\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"Label\"\u003e\u003cspan class=\"Bold\"\u003eHow to Implant:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"Label\"\u003e\u003cb class=\"Bold\"\u003eFor use with the Synovex Applicator\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"BodyKwn\"\u003eStudy the following instructions carefully, then proceed step by step, until the technique becomes routine. Many head can be implanted per hour by an experienced team, one member of which should be assigned to do nothing but the implantation. Care should be taken to insure the hands of the person administering the implant are clean and only sanitary instruments are used.\u003c\/p\u003e\n\u003cp class=\"Label\"\u003e\u003cb class=\"Bold\"\u003eSTEP 1 Loading The Applicator\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/rjmatthews.cvpservice.com\/public\/product\/ssdLabel\/docFile?uuid=6e2b20fb-6c5c-4cd0-aac4-62adfbaccfff\" border=\"0\"\u003e\n\u003cp class=\"Body\"\u003eLoad the applicator following the directions outlined in the instruction manual accompanying each applicator. When using metal revolver style applicator, use orange adapter kit.\u003c\/p\u003e\n\u003cp class=\"Body\"\u003e\u003cb class=\"Bold\"\u003eAdditional information for the individual applicator user guides can be found at:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cb class=\"Bold-Underline\"\u003ewww.growwithsynovex.com\u003c\/b\u003e\u003cb class=\"Bold\"\u003e.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"Label\"\u003e\u003cb class=\"Bold\"\u003eSTEP 2 Restraint\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/rjmatthews.cvpservice.com\/public\/product\/ssdLabel\/docFile?uuid=ceb4208a-0561-473a-a9ff-4b945f12708b\" border=\"0\"\u003e\n\u003cp class=\"Body\"\u003eThe animal must be confined in a restraint mechanism (squeeze chute or head gate). The implant site on the back of the ear should be prepared by scrubbing with a firm bristled brush that has been soaked in a germicidal solution.\u003c\/p\u003e\n\u003cp class=\"Body\"\u003e\u003cb class=\"Bold\"\u003eNote:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eIf implanting horned cattle, greater safety is provided when the head is controlled by the use of a bull lead (nose tongs).\u003c\/p\u003e\n\u003cp class=\"Label\"\u003e\u003cb class=\"Bold\"\u003eSTEP 3 Implant Site\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/rjmatthews.cvpservice.com\/public\/product\/ssdLabel\/docFile?uuid=073eed05-54c5-4aac-a54b-271c60e56163\" border=\"0\"\u003e\n\u003cp class=\"Body\"\u003eDivide the ear into three imaginary sections as illustrated. The implanted pellets should be deposited in the center one-third of the ear as shown. To accomplish this, the applicator needle should be inserted in the\u003cspan\u003e \u003c\/span\u003e\u003cb class=\"Bold\"\u003eouter\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eone-third of the ear as indicated by the “X” in the illustration. Implanting too close to the head may cause abnormal sexual behavior. Care should be taken to avoid severing the major arteries of the ear.\u003c\/p\u003e\n\u003cp class=\"Label\"\u003e\u003cb class=\"Bold\"\u003eSTEP 4 Insert Needle\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/rjmatthews.cvpservice.com\/public\/product\/ssdLabel\/docFile?uuid=f150160a-7ca7-4687-9927-0b7f694b8851\" border=\"0\"\u003e\n\u003cp class=\"Body\"\u003eGrasp the ear with one hand. Holding the applicator firmly with the other hand, penetrate the skin at the point shown by the “X”. Thrust the needle under the skin taking care not to penetrate the cartilage. Ease the applicator forward (toward the base of the ear) until the full needle length is beneath the skin.\u003c\/p\u003e\n\u003cp class=\"Label\"\u003e\u003cb class=\"Bold\"\u003eSTEP 5 Pellet Implantation\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/rjmatthews.cvpservice.com\/public\/product\/ssdLabel\/docFile?uuid=da2dc013-dc1d-4773-b80d-7f1cf212bb2f\" border=\"0\"\u003e\n\u003cp class=\"Body\"\u003eWhen the needle is completely inserted, activate the instrument by squeezing the trigger completely. Refer to instructions for individual applicator.\u003c\/p\u003e\n\u003cp class=\"Label\"\u003e\u003cb class=\"Bold\"\u003eSTEP 6 Inspection\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/rjmatthews.cvpservice.com\/public\/product\/ssdLabel\/docFile?uuid=8000372e-0fca-4f9b-9a19-7ef2d60cd046\" border=\"0\"\u003e\n\u003cp class=\"Body\"\u003eCheck the implant site. If properly administered, the implants should lie in a straight line under the skin. Re-cock the applicator. Disinfect the applicator needle in a germicidal solution. The applicator is now ready to implant the next animal.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWithdrawal Periods and Residue Warnings:\u003c\/h3\u003e\n\u003cp\u003eNo withdrawal period is required when used according to labeling.\u003c\/p\u003e\n\u003cp\u003eDo not use in beef calves less than 2 months of age, dairy calves, and veal calves. A withdrawal period has not been established for this product in pre-ruminating calves.\u003c\/p\u003e\n\u003cp\u003eDo not use in dairy cows or in animals intended for subsequent breeding. Use in these cattle may cause drug residues in milk and\/or in calves born to these cows.\u003c\/p\u003e\n\u003cp\u003eImplant pellets subcutaneously in ear only. Any other location is a violation of Federal law. Do not attempt salvage of implanted site for human or animal food.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUser Safety Warnings: \u003c\/strong\u003eNot for use in humans. Keep out of reach of children.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnimal Safety Warnings: \u003c\/strong\u003eBulling has occasionally been reported in implanted steers and heifers. Vaginal and rectal prolapse, udder development, ventral edema and elevated tailheads have occasionally been reported in heifers administered SYNOVEX ONE Grower implants.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Zoetis","offers":[{"title":"Default Title","offer_id":42546974785694,"sku":"","price":648.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0401\/2186\/0254\/files\/synovex-one-grower-cattle-implants-houlihan-saddlery-llc-1.jpg?v=1737570023","url":"https:\/\/houlihansaddlery.com\/products\/synovex-one-grower","provider":"Houlihan Saddlery LLC","version":"1.0","type":"link"}